PRODUCTS

V810i S2EX

description

V810i S2EX : Advanced 3D X-ray Inspection System (AXI)


World fastest and best test coverage AXI system for SMT PCB 

assembly line

HTTP
SystemV810i S2 Series
System controllerIntegrated controller with 8 Core Intel Xeon processors
Operating systemWindows 10 Pro (64 bit)
Test Development Environment
User interfaceMicrosoft Windows based software solution with easy-to-use GUI and password-protected user levels
Off-line test development softwareOptional for off-line PC
CAD conversion toolSupport 4 different types of CAD in V810i software and optional software available to translate other CAD data to ViTrox's format
Typical test development time4 hours to 1.5 days to convert raw CAD file and develop application
Line Integration
Transport heights865mm-1025mm
Line communication standardSMEMA, HERMES
Barcode readersCompatible with most industry standard barcode readers
Performance Parameters*
False Call rate500-1000ppm
Minimum features detection capability
Joint pitch10.3mm and above
Short width20.045mm
Solder thickness0.0127mm
Allowable Panel Characteristics **StandardDL
Maximum PCB Size (L x W)609.6mmx482.6mm (24"x19")Dual Lane: 416.6mmx206mm (16.4"x8.1")
Single Lane: 416.6mmx400mm (16.4"x15.7")
Minimum PCB Size (L x W)76.2mmx76.2mm (3"x3")76.2mmx101.6mm (3"x4")
Maximum PCB inspectable area609.6mmx474.9mm (24"x18.7")Dual Lane: 416.6mmx198.1mm (16.4" x 7.8")
Single Lane: 416.6mmx391.1mm (16.4"x15.4")

(Not supported longboard scanning)
Maximum PCB thickness7mm (275 mils)5mm (196mils)
Minimum PCB thickness0.5mm (20 mils)
PCB warpDownside < 3.3mm; Upside < 1.5mm
Maximum PCB weight4.5kg
Top Clearance of PCB50mm @ 23µm resolution
38mm @ 19µm resolution
38mm @ 10.5µm resolution#
11mm @ 11µm resolution
11mm @ 6µm resolution#
(Calculated from Board Top surface)
Bottom Clearance of PCB70mm60mm
PCB edge clearance3mm
100% Press-fit testabilityYes (With PSP2 / PSP2.1 feature)
PCB Temperature40℃
Installation Specification
Power Supplies200–240 VAC three phase; 380–415 VAC three phase wye (+/- 5) (50Hz or 60Hz)
Air requirement552kPA (80psi)
System footprint (Width X Depth X Height)1566mmx2145mmx1972mm
Total system weight~3800kgs~3850kgs
**Note:
1. Panels are handled on width edges. Panels with edge cut outs may require the use of a carrier.
2. Maximum panel size dimensions and weight must include carrier if applicable
3. Smaller panels are possible with the use of panel carriers.
4. With panels of this thickness, imaging results can be affected by PCBA layout.
5. Measured from the bottom of the panel including a maximum warp.

*Note:
1. Assuming pad width is 50% of pitch.
2. The reported values for minimum feature detection assume that the feature is in a single plane of focus and that there are no X-ray absorbers in the X-ray path or in the immediate area of the feature other than those found in a typical multi-layer printed circuit board.

#2x2 binning camera configuration. Hardware upgrade is required on old system.


contact us
Add:1106b, block a, Qianhai Times Square, Baoan Central District, Shenzhen
Tel:0755-23344826
Fax:0755-23344825
E-mail:office@mk-t.com.cn